6.18 Set Paper Path ”PP” 03H 00H 00H m1 m2
Format:
“PP” 03H 00H 00H m1 m2
Parameters:
The parameter m1 is one byte binary value, and indicates the paper path:
Paper m1
Manual feed 02H
Roll paper 03H
Reserved 04H - FFH
The parameter m2 is one byte binary parameter, and indicates the paper path
Number. This has no meaning with Stylus Pro 7000
Function
- The paper path default environment is set.
- If the selected paper path by the panel is different from the paper path specified
by this command, due to mismatch paper an error message appears with Stylus
Pro 7000.
- If parameter m1 is out of range (00H, 01H, 04H-FFH), this command is
ignored and the current setting is maintained.
- This command is only valid in remote mode.