
48
Dukane Manual Part No. 403–566–01
DPC
™
II Plus and EZ Welder System – User’s Manual
Press Control Module
Part No. 110–3938
This optional module enables the DPC II Plus to
control a Dukane Model 210, 220 or 410 press or
custom automation. This module is also installed
on a EZ Welder™ System. The module is
illustrated in Figure 5–8. The cabling hookup to a
Dukane press system is shown in Figure 3–8.
Pin No. Type Function Signal Description
1 Input Activation Switch 1 Normally Open (N.O.) dry contact closure to ground
2 Input Activation Switch 2 Normally Open (N.O.) dry contact closure to ground
3 Input Hardware Abort Power In Normally Closed (N.C.) emergency switch contact
4 Input Software Abort Normally Open (N.O.) dry contact closure to ground
5 Ground Internal Ground Internal Ground (Gnd)
6 Ground Internal Ground Internal Ground (Gnd)
7 Ground Internal Ground Internal Ground (Gnd)
8 Input Automation Input Normally Open (N.O.) dry contact closure to ground
9 +22V DC
Hardware Abort Power Out
Normally Closed (N.C.) emergency switch contact
J901
Thruster Cable
Connection
J902 Press
Base Cable
Connector
Press Control
Module
P/N 110–3938
1
1
5
9
6
1836
19
Molex
DB–9
36–Contact
Subminature D
Figure 5–8 Press Control Module
Table 5—
V J902 Press Base Connector Pinout
Figure 5–9 Press
Connector Pin
Identification