SPECIFICATIONS
Natural Gas Propane/LP
Btu (Variable) 20,000/39,000 20,000/39,000
Type Gas Natural Gas Only Propane/LP Only
Ignition Piezo Piezo
Pressure Manifold 3.5" W.C. 8.0" W.C.
Inlet Gas Pressure (in. of water)
Maximum 10.5" 14"
Minimum* 5" 11"
Shipping Weight 32 lbs. 32 lbs.
* For input adjustment
SERVICE HINTS
When Gas Pressure Is Too Low
pilot will not stay lit
burners will have delayed ignition
heater will not produce specified heat
propane/LP gas supply may be low
You may feel your gas pressure is too low. If
so, contact your local natural or propane/LP
gas supplier.
TECHNICAL
SERVICE
You may have further questions about in-
stallation, operation, or troubleshooting. If
so, contact DESA International’s Technical
Service Department at 1-866-672-6040.
You can also visit DESA International’s
technical services web site at
www.desatech.com.
WIRING DIAGRAM
Note:
For proper operation of optional ac-
cessories, the wires from the switch to the
control must be connected exactly as shown.
AUTO
OFF
ON
Thermopile
REPLACEMENT
PARTS
Note:
Use only original replacement parts.
This will protect your warranty coverage for
parts replaced under warranty.
PARTS UNDER WARRANTY
Contact authorized dealers of this product. If
they can’t supply original replacement part(s),
call DESA International’s Technical Service
Department at 1-866-672-6040. When call-
ing DESA International, have ready
your name and address
model and serial numbers of your heater
how heater was malfunctioning
type of gas used (propane/LP or natural gas)
purchase date
Usually, we will ask you to return the part to
the factory.
PARTS NOT UNDER
WARRANTY
Contact authorized dealers of this product. If
they can’t supply original replacement part(s),
call DESA International at 1-866-672-6040
for referral information. When calling DESA
International, have ready
model number of your heater
the replacement part number