• Use pipe that is the same size as
the air tank outlet. Piping that is
too small will restrict the flow of
air.
• If piping is over 100 feet long,
use the next larger size.
• Bury underground lines below
the frost line and avoid pockets
where condensation can gather
and freeze. Fill lines with air pres-
sure before covering to make
sure pipe joints are free from
leaks.
• Install a flexible coupling
between the air discharge outlet
and main air distribution line to
allow for vibration.
NOTE: The shut-off valve is not sup-
plied with this unit. You must purch-
sase the shut-off valve separately.
• A separate regulator is recom-
mended to control the air pres-
sure. Air pressure from the air
tank is usually too high for indi-
vidual air driven tools.
Slope pipe down in direction of air flow.
lines.