50PCV006-060 UNITS
NOTES:
1. Shaded areas are recommended service areas. Installer should take care to comply with
all building codes and allow adequate clearance for future field service.
2. Front and side access is preferred for service access. However, all components may be
serviced from the front access panel if side access is not available except on 50PCV009-
030 with front return.
3. Discharge flange is field installed.
4. Condensate is 3/4 in. (19.1 mm) FPT.
5. Units shipped with filter rails. These rails should be removed for return duct connection.
See WSHP Accessory Price Page for accessory air filter frame with duct collar.
50PCV
UNIT
SIZE
OVERALL CABINET WATER CONNECTIONS ELECTRICAL KNOCKOUTS
DISCHARGE CONNECTION
DUCT FLANGE INSTALLED
(0.10 in., 2.5 mm)
RETURN CONNECTION
USING RETURN AIR
OPENING
A
Width
B
Depth
C
Height
12 3
Size
(IPT)
J
1/2-in.
(1.3 cm)
K
1/2-in.
(1.3 cm)
L
3/4-in.
(1.3 cm)
MN
O
Supply
Width
P
Supply
Depth
QR
S
Return
Depth
T
Return
Height
U
DE FG
HI
Low
Voltage
Low
Voltage
Power
Supply
Loop In Loop Out
006-
012
in. 19.1 19.1 22.0 1.4 1.6 9.5 1.6 6.1 1.6
1
/
2
2.9 5.9 8.9 8.9 5.1 9.0 9.0 5.5 2.1 16.2 9.9 0.7
cm 48.5 48.5 55.9 3.6 4.1 24.1 4.3 15.6 4.1 1.3 7.3 14.9 22.5 22.7 12.9 22.9 22.9 14.0 5.3 41.1 25.1 1.9
015
in. 21.5 21.5 39.0 1.9 1.4 13.8 1.4 8.1 1.4
1
/
2
4.1 7.1 10.1 6.4 3.8 14.0 14.0 5.3 2.3 18.3 20.9 0.7
cm 54.6 54.6 99.1 4.8 3.6 35.1 3.6 20.6 3.6 1.3 10.5 18.1 25.7 16.1 9.5 35.6 35.6 13.6 5.8 46.5 53.1 1.9
018
in. 21.5 21.5 39.0 1.9 1.4 12.9 1.4 8.1 1.4
1
/
2
4.1 7.1 10.1 6.4 3.8 14.0 14.0 5.3 2.3 18.3 20.9 0.7
cm 54.6 54.6 99.1 4.8 3.6 32.8 3.6 20.6 3.6 1.3 10.5 18.1 25.7 16.1 9.5 35.6 35.6 13.6 5.8 46.5 53.1 1.9
024
in. 21.5 21.5 40.0 1.9 1.4 13.8 1.4 8.1 1.4
3
/
4
4.1 7.1 10.1 6.4 3.8 14.0 14.0 5.3 2.3 18.3 20.9 0.7
cm 54.6 54.6 101.6 4.8 3.6 35.1 3.6 20.6 3.6 1.9 10.5 18.1 25.7 16.1 9.5 35.6 35.6 13.6 5.8 46.5 53.1 1.9
030
in. 21.5 21.5 40.0 1.9 1.4 15.2 1.4 8.1 1.4
3
/
4
4.1 7.1 10.1 6.4 3.8 14.0 14.0 5.3 2.3 18.3 20.9 0.7
cm 54.6 54.6 101.6 4.8 3.6 38.6 3.6 20.6 3.6 1.9 10.5 18.1 25.7 16.1 9.5 35.6 35.6 13.6 5.8 46.5 53.1 1.9
036
in. 21.5 26.0 45.0 1.9 1.4 15.7 1.4 8.1 1.4
3
/
4
4.1 7.1 10.1 6.4 3.8 14.0 14.0 5.1 2.3 22.8 23.9 0.7
cm 54.6 66.0 114.3 4.8 3.6 39.9 3.6 20.6 3.6 1.9 10.5 18.1 25.7 16.1 9.5 35.6 35.6 13.1 5.8 57.9 60.7 1.9
042
in. 21.5 26.0 45.0 1.9 1.4 16.6 1.4 8.1 1.4
3
/
4
4.1 7.1 10.1 6.4 3.8 14.0 14.0 5.1 2.3 22.8 23.9 0.7
cm 54.6 66.0 114.3 4.8 3.6 42.0 3.6 20.6 3.6 1.9 10.5 18.1 25.7 16.1 9.5 35.6 35.6 13.1 5.8 57.9 60.7 1.9
048
in. 24.0 32.5 46.0 1.9 1.4 16.6 1.4 8.1 1.4 1 4.1 7.1 10.1 6.9 7.3 16.0 18.0 5.1 2.3 29.3 22.5 0.7
cm 61.0 82.6 116.8 4.8 3.6 42.2 3.6 20.6 3.6 2.5 10.5 18.1 25.7 17.4 18.4 40.6 45.7 13.1 5.8 74.4 57.0 1.9
060
in. 24.0 32.5 46.0 1.9 1.4 16.7 1.4 8.1 1.4 1 4.1 7.1 10.1 6.9 7.3 16.0 18.0 5.1 2.3 29.3 22.5 0.7
cm 61.0 82.6 116.8 4.8 3.6 42.4 3.6 20.6 3.6 2.5 10.5 18.1 25.7 17.4 18.4 40.6 45.7 13.1 5.8 74.4 57.0 1.9
Fig. 3 — 50PCV Unit Dimensions
LEGEND
ASP — Alternate Service Panel
BSP — Blower Service Panel
CAP — Control Access Panel
CSP — Compressor Service Panel
FPT — Female Pipe Thread
HV — High Voltage
LV — Low Voltage
a50-8696