![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/2/99/29938a7f-66c1-4acd-9cce-1f6d611c5cc6/29938a7f-66c1-4acd-9cce-1f6d611c5cc6-bg42.png)
66 en | Advanced configuration menu Divar XF
F.01U.135.429 | 2.5 | 2009.08 Installation manual Bosch Security Systems
– If DHCP is disabled, fill in the IP address, the Subnet mask, the Default gateway, and the
DNS Server address. If required, change the default HTTP port (80) to a new value.
– Restrict the network bandwidth by entering a Mbps value between 0.1 and 100 for the
Bandwidth limit.
–The MAC address is read only; it shows the MAC address of the DVR.
– Cable connected shows the status of the physical network connection.
6.8.2 IP Range
– Eight IP ranges can be entered to allow access.
– Enter the same begin and end address to specify a single IP address. Enter different
begin and end addresses to specify an IP address range.
6.8.3 Monitor Streaming
The remote monitor streaming function allows monitor output A and/or B to be streamed
remotely via one or more of the analog video inputs. The main advantage of using this feature
is that multi-screen images can be viewed remotely using just one video stream, thus requiring
only a limited amount of network bandwidth and computer resources.
Each of the analog video inputs can be configured as:
– Camera input (default).
– Streaming output A (input is used to stream monitor output A).
– Streaming output B (input is used to stream monitor output B).
Note:
Disable the recording of a channel used for monitor streaming in the Recording tab.
Figure 6.10 Network menu - Monitor streaming