![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/4/bb/4bb2179f-1493-4132-a7e8-23cf9f69f84f/4bb2179f-1493-4132-a7e8-23cf9f69f84f-bg34.png)
52 en | Configuring the AutoDome 700 Series AutoDome 700 Series IP PTZ Camera
F.01U.215.777 | 1.0 | 2011.07 User Manual Bosch Security Systems, Inc.
4.44 Advanced Mode: Interfaces
4.45 Alarm Inputs
Select the type of input for each physical alarm. Select from either N.O. (Normally Open) or
N.C. (Normally Closed) and provide an optional name for each input.
4.46 Relay
The AutoDome 700 Series incorporates one (1) open collector alarm output. Use the following
settings to configure the relay.
Idle State
Specify either Open or Closed idle state.
Operations Mode
Select one of the following modes for operation: Bistable, 0.5 s, 1 s, 5 s, 10 s, or 60 s.
Relay Follows
Select one of the following actions that the AutoDome performs after the relay is triggered:
–Off
–Connection
–Video Alarm 1
–Motion Alarm 1
– Local Input 1
–Remote Input 1
Relay Name
Type an optional name for the relay connection, up to 20 characters.
Trigger Relay
Click the Relay 1 button to test the relay connection.
4.47 Advanced Mode: Network
4.48 Network Access
The settings on this page are used to integrate the AutoDome 700 Series into an existing
network.
Some changes only take effect after the unit is rebooted. In this case, the Set button changes
to Set and Reboot.
1. Make the desired changes.
2. Click the Set and Reboot button. The AutoDome 700 Series is rebooted and the changed
settings are activated.
CAUTION!
If you change the IP address, subnet mask or gateway address, the AutoDome 700 Series is
only available under the new addresses after the reboot.