6.2 Video & Audio
Use this menu to configure the video and audio inputs.
On DHR 730 models tabs 1-8 are for the analog cameras. Higher tabs are for IP cameras.
On DHR 750 models tabs 1-16 are for the analog cameras. Higher tabs are for IP cameras.
On DNR 730 models tabs 1-16 are for IP cameras.
On DNR 750 models tabs 1-32 are for IP cameras.
On models with expanded memory, (revision B models) the bitrates tab follows the camera
number tabs.
6.2.1 Analog Channels
The tabs 1-8 or 1-16 across the top of the menu contain the settings for each of the analog
inputs on a digital hybrid recorder.
Figure 6.4 Configuration menu - Video & Audio - Analog camera
A General tab and a Control tab are available for each analog camera.
General tab
– Enter a name for the selected input. The name can be up to 16 characters long.
–The Enable video input setting enables (default) or disables the video and corresponding
audio inputs.
– Auto contrast - enabled to let the system automatically adjust the contrast for the video
input.
– Contrast - can be set manually with the slider if Auto contrast is disabled.
– Enable Audio input when an audio source is connected.
–The Level meter indicates the strength of the audio input signal.
– Use the Gain slider to adjust the input sensitivity.