INSTALLATION INSTRUCTIONS (continued)
6
CAUTION:
Electric Shock
Hazard
Brewer must be properly
grounded to a reliable earth
ground to prevent possible
shock hazard. Do not assume a
plumbing line will provide such a
ground. Electrical shock may
cause serious injury.
IMPORTANT:
Initial set-up must be performed
by a qualified installer or
qualified service technician.
Improper set-up will damage the
brewer and void the warranty.
IMPORTANT:
Complete water line installation
before connecting brewer to
electrical power.
MAKE SURE THE FRONT
PANEL "TANK HEATER"
SWITCH IS IN THE OFF
POSITION BEFORE
CONNECTING BREWER TO
ELECTRICAL POWER.
DO NOT turn the TANK
HEATER switch on until the
water tank is filled. Heating
element must be completely
submerged in water at all times.
Damage to the brewer caused
by operating the heating
elements dry is NOT covered by
warranty.
ELECTRICIAN’S INSTALLATION INSTRUCTIONS
Refer to Electrical Specifications, page 1.
Brewer requires a dedicated single-phase circuit:
Model 9311 120/240 Volt AC, 50/60 Hz 4-Wire 20 Amps.
INITIAL SET-UP INSTRUCTIONS
Plumber’s and Electrician’s installation procedures must be
completed before proceeding with the set-up.
Be sure all electrical connections are secure, and that all
plumbing connections are secure and leak-proof.
1. CHECK BREWER FOR PROPER CONFIGURATION
Make sure spray disk gasket is in place INSIDE of spray
head.
Make sure spray disk is properly installed.
Check hot water faucet for proper operation.
2. FILL WATER TANK
Be sure TANK HEATER switch is OFF, then connect brewer
to electric power.
Insert an empty brew chamber under the brew head. Place
an empty satellite in position. Turn the VOLUME SELECTOR
switch to 1 GAL.
Press START. Water will begin filling the tank. Repeat until
water flows from the brew chamber. For initial start-up, tank
requires two or more 1 GAL. cycles to fill.
3. CHECK HEATING
Press TANK HEATER switch ON. Water in tank will heat
to brewing temperature in approximately 30 minutes. When
the water temperature reaches the brew temperature set
point, the READY-TO-BREW light will glow.
Hold a suitable container under the hot water faucet, then
open the faucet . Continue drawing water until all trapped air
is expelled.
661 74415 9311 Single Satellite Brewer