7 8
Meter Functions – Resistance
(
Ω
)
IMPORTANT:
If you are testing an
application that has capacitors
in the circuit, be sure to turn the
power OFF on the test circuit and
discharge all capacitors. Accurate
measurement is not possible if
external or residual voltage is
present.
Select the
resistance(
Ω
)
range with the rotary switch.
Insert:
Black lead in
COM
terminal.
Red lead in V-
Ω
-RPM
terminal.
Touch the test lead probes across
the resistor to be tested.
Meter Functions – Diode Check ( )
IMPORTANT: Turn the power OFF to
the test circuit
Select the
Diode Check
( )
setting with the rotary switch.
Insert:
Black lead in COM terminal.
Red lead in
V-
Ω
-RPM
terminal.
Touch the Black test probe to the
negative (-) side of the diode.
Touch the Red test probe to the
positive (+) side of the diode.
Reverse the probes : Black to the
positive (+) side and Red to the
negative (-) side.
Note:
A
〃
good
〃
diode will read low in
one direction and high in the other
direction when the probes are
reversed (or vice versa).
A defective diode will have the same
reading in both directions or read
between 1.0 to 3.0V. in both directions
Diode - to +
Reverse
Probes
+ to -
.4 to .9V OL
Good
OL .4 to .9V
OL 1.0 to 3.0V
1.0 to
OL
.4 to .9V .4 to .9V
Bad
OL
.000V
OL
.000V