
GEQ
SHIFT
This unit provides the following 5 different programmed
equalization curves.
ROCK: Powerful sound emphasizing treble and bass
POP: More presence in the vocals and midrange
JAZZ: Accented lower frequencies for jazz-type music
CLASSIC: Enriched sound with heavy bass and fine treble.
LATIN: JAZZ- type equalization curve with higher frequencies
Press GEQ, and turn MULTI JOG to select one of the
programmed equalization curve within 4 seconds.
GRAPHIC EQUALIZER
“GRAPHIC EQUALIZER appears (except “GEQ OFF) and the
GEQ mode is displayed cyclically as follows.
~ ROCK- POP --+ JAZZ--+ CLASSIC- LATIN ~
L
‘---------- Programmed mode ----------:
GEQ OFF — M4 — — — Ml
J
(cancel) !...... M~nual m~d~ . . . . . .
To display the current GEQ mode
Press GEQ. The current mode is displayed for 4 seconds.
To cancel the selected mode
Press GE(2, and turn MULTI JOG to select” GEQ OFF within 4
seconds, “GRAPHIC EQUALIZER disappears.
To select with the remote control
Press GEQ repeatedly while pressing SHIFT. The GEQ mode is
displayed cyclically as above.
To change the spectrum analyzer display
3
patterns of spectrum analyzer display can be shwon.
Press DISP once, and turn MULTI JOG within 4 seconds to select
the desired spectrum analyzer display.
SETTING A NEW EQUALIZATION CURVE
MANUALLY
The equalization curve can be customized to suit your preference.
1
Press LOW.
The lowest level frequency indicator flashes for 4 seconds.
2 Within 4 seconds, turn MULTI JOG to adjust the
level of the lowest frequency.
3 Press HIGH.
The highest level frequency indicator flashes for 4 seconds.
4 Within 4 seconds, turn MULTI JOG to adjust the
level of the highest frequency.
The frequency level indicators of between the lowest and the
highest are adjusted accordingly.
MEMORIZING THE NEW EQUALIZATION
CURVES
Up to 4 customized equalization curves can be stored as the
manual modes Ml - M4.
1
2
3
4
Set a new equalization curve with HIGH, LOW and
MULTI JOG.
See “SETTING ANEW EQUALIZATION CURVE MANUALLY”.
The created curve is displayed for 4 seconds.
Within 4 seconds, press ENTER.
“M 1” flashes on the display for 4 seconds.
● If this step is not completed within 4 seconds, press GEQ
first to display “GEQ ON”. Then press ENTER wtihin 4
seconds.
Within 4 seconds, turn MULTI JOG to select one
of the manual modes Ml - M4 to store the curve.
Within 4 seconds, press ENTER.
The new equalization curve is stored.
To select the stored equalization curve
Press GEQ, and turn MULTI JOG to select one of the manual
modes Ml - M4 within 4 seconds.
7 ENGLISH