Western Telematic RSM-16 Video Gaming Accessories User Manual


 
5-23
Configuration
The Port Parameters menu also offers two additional items used to set the priority of
Syslog messages generated by this port:
Facility: The facility under which this port will log messages.
(Default = Local_0.)
Level: The severity (or priority) of messages generated by this port. (Default =
Emergency.)
SNMP Trap Level: Enables/disables the SNMP Trap function and sets the byte
level that will generate traps at this port. If set to "0" (zero), then SNMP Traps are
disabled at this port.
If this value is set between 1 and 32,767, then the SNMP Trap function is enabled,
and traps will be sent to the SNMP Managers whenever the buffer for this port
reaches the specified level. For more information, please refer to Section 10.
(Default = Off.)
Note:
The SNMP Trap feature only applies to Buffer Mode Ports.
This option is not available to RS232 Ports 1 or 2. This is because Ports 1
and 2 are reserved as SetUp Ports, and cannot be configured as Buffer Mode
Ports.
5.7.3. Configuring the Internal Modem
The RSM's internal modem can be configured via the Text Interface or Web Browser
Interface. The configuration menu for the internal modem is identical to the
configuration menus for the RS232 Serial Ports, except that the Port Mode for the
Modem Port is always set at "Modem Mode" and the Any-to-Any Mode, Buffer Mode
and Passive Mode are not available. To access the Modem Port configuration menu,
proceed as follows:
Text Interface: Use the /P command to access the Modem Port Configuration
Menu:
RSM-8 Units: Type /P 9 and press [Enter].
RSM-16 and RSM-16DC Units: Type /P 17 and press [Enter].
RSM-32 and RSM-32DC Units: Type /P 33 and press [Enter].
Web Browser Interface: Click on the Serial Port link on the left hand side of the
screen to display the Port Selector Menu. Use the Port Selector Menu, to select the
Modem Port as follows:
RSM-8 Units: Click on the down arrow to display the drop down menu, highlight
port 9 and then click on the "Select Port" button.
RSM-16 and RSM-16DC Units: Click on the down arrow to display the drop
down menu, highlight port 17 and then click on the "Select Port" button.
RSM-32 ad RSM-32DC Units: Click on the down arrow to display the drop
down menu, highlight port 33 and then click on the "Select Port" button.
For a description of the various parameters that can be configured via the Modem Port
Configuration Menu, please refer to Section 5.7.2.