The FP0 DPS2 can operate either as a DP Slave module or as a remote I/O
system to which different decentralised inputs and outputs can be connected.
A DIP switch can be used to switch between the two modes:
Mode 1:
DP Slave module. Connect the FP0 or FPΣ (Sigma) CPU + expansion modules
to the PROFIBUS network.
Mode 2:
Remote I/O. Connect up to three expansion modules without CPU to the
PROFIBUS network.
In remote I/O mode, the unit can be connected to any PLC which offers a
PROFIBUS communication interface, making it totally independent of
Panasonic PLCs.
Item Description
Type designation
PROFIBUS standards complied with
FP0 DP Slave unit, Ord. No. FP0DPS2
EN 50170, DIN 19245 Part 1 and Part 3
Baud rates
9.6 / 19.2 / 93.75 / 187.5 / 500 / 1,500 / 3,000 / 6,000 / 12,000 Kbaud
automatic baud rate detection
Range of addresses that can be set 0..125
PROFIBUS connection
Configuration
9-pin Sub-D connector
2 words input / 2 words output, up to 6 words input / 6 words output if no other expansion is connected
Remote I/O, max. 3 FP0 expansion units
FP0 communication
Via FP0 system bus
Power supply 24VDC (21.6VDC … 26.4VDC)
Max. power consumption 100mA
F
P0-DPS sp
e
c
i
f
i
c
a
t
i
ons
DP-Slave
Remote I/O
PLC
(Master)
PLC
(Slave)
Remote I/O
(Slave)
FP0 DP Slave
FP
(Sigma) DP Slave
DP Slave Remote I/O
Configuration with digital I/O
up to 96 transistor I/O or up to
48 relay I/O are possible
DP Slave Remote I/O Configuration
with analogue I/O up to 12 outputs
or 24 analogue inputs or up to 24
thermocouple inputs are possible
FP2 DP or FMS Master
Specially by developed software tools ensure
easy configuration and start-up of PROFIBUS
products.
PROFIBUS DP-Configurator AFP86910
07/2007