10.05 Parameter settings
Parameter settings are described in the separate operations manual for
the drive, and may only be changed by qualifi ed technicians!
10.05.01 Parameter list for control unit P40 ED and P40 PD2
Group
Parameter
Description
User lever
Setting range
Set value P40 ED
Set value P40 PD2
1
105 Speed for start backtackl B, C 300 - 2000 1200 1200
110 Speed for end backtack B, C 300 - 2000 1200 1200
6
606 Speed min B, C 30 - 300 180 180
607 Speed max. B, C 300 - 6000
▲▲
6
609 Cutting speed 1 B, C 60 - 300 180 180
660 Bobbin thread control
0 = off, 1 = thread monitor,
2 = reverse counter
A, B,
C
0 - 2 0 -
668 Thread wiper/thread blower
1 = on; 0 = off
B, C 0 - 1 0 -
7
700 Needle position 0
(needle reference position
B, C 0 -255 * *
702 Needle position 1 (needle lowered) B, C 0 - 255 90 90
703 Needle position 2 (take-up lever raised) B, C 0 - 255 236 236
705 Needle position 5 (end cutting signal 1) B, C 0 - 255 200 200
706 Needle position 5 (start cutting signal 2) B, C 0 - 255 136 136
707 Needle position 9 (start thread tension
release/start thread catcher)
B, C 0 - 255 164 164
760 Multiplier for the fi xed value (200)
stitch count
A,B,
C
0 - 250 5 -
797 Hardwaretest (OFF / ON ), B, C OFF OFF
799 Selected machine class C 1 - 3 1 2
8
800 Rotating direction of the motor C 0 - 1 0 0
802 Main drive reduction ratio
0 = 1:1, 1 = variable
C 0 - 1 - 0
V
See Chapter 3 Specifi cations
*
Adjustment see Chapter 8.05 Basic position of the machine drive unit.