Turn the water on to the handshower. Turn the temperature
control stem until the output water is the desired maximum high
temperature -- usually 110
o
*. Turn the water off.
Replace the stop ring so that the tooth is against the high
temperature limit stop. Replace the clip.
Justify the handle.
*Please know and follow all applicable local plumbing codes when setting
the high temperature limit stop.
User Instructions
Using the Thermostatic Mixer
Turn the handle clockwise to make the water cooler.
Turn the handle counter-clockwise to make the water warmer. When the safety
stop override is at the 12:00 position, the output water is 100
o
F, the handle
will stop. If a user wants water hotter than 100
o
F, press the safety stop over-
ride button and continue turning the handle counter-clockwise.