A SERVICE OF

logo

10
Justify the Thermostatic Mixer Handle
Set the High Temperature Limit Stop (optional)
Turn the water on to the
handshower.
Turn the thermostatic mixer
handle until the output water
measures 100
o
on a ther-
mometer. Turning the handle
clockwise makes the water
cooler, counter-clockwise
makes the water warmer.
Turn the water off.
Remove the thermostatic mixer handle.
Remove the clip and the stop ring from the stem of the thermo-
static mixer.
Loosen the thermostatic mixer
handle screw. Remove the
handle.
Replace the handle so that
the safety stop override but-
ton is at the 12:00 position.
Tighten the set screw.