York Y32 Air Conditioner User Manual


 
246653-YTG-E-0108
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
TECHNICAL GUIDE
MILLENNIUM
®
SINGLE PACKAGE ROOFTOP UNITS
Y
32, Y33 & Y34
25, 30, & 40 TON
25 TON (10 EER)
30 & 40 TON (9.5 EER)
®
30 TON UNIT SHOWN
ISO 9001
Certified Quality
Management System
TOMORROW’S UNIT TODAY
GENERAL
Introducing the YORK Millennium 25, 30, & 40 ton rooftop
line - units designed to provide peak performance and value
both today and for years to come. Millennium units are manu-
factured at an ISO 9001 registered facility, and each rooftop
is completely computer-run tested prior to shipment.
The Millennium is designed to be flexible enough to meet
your needs today and in the future. The true value of YORK’s
Millennium is that it can be designed to fit any need, from
cooling only, constant volume applications to variable air vol-
ume systems with variable frequency drive.
FEATURING:
Cooling Only Units
Cooling/Gas Heating Units (Natural) Standard or
Modulating Gas Heat available
Cooling/Electric Heating Units
Cooling/Hot Water Heating Units
Cooling/Steam Heating Units
Industry Leading Efficiency
Double Wall Construction
Stainless Steel or Powder Coated Drain Pan
Multiple Scroll Compressors
Multiple Refrigeration Circuits
Upgradable Motor Efficiency
Enhanced Filtration
Vibration Isolated Supply Fan and Motor
Technicoated Evaporator and Condenser Coils
High Capacity Evaporator Coils
Single Power Point Connection
Easy Access Hinged Doors
Variable Air Volume
Constant Air Volume
Factory Installed Economizers/Disconnect/Convenience
Outlet/Control Options
•Low Profile
MILLENNIUM SIMPLICITY
®
ELITE™ FEATURES:
Single Button Programming and LED Display
Designed to operate on both constant and variable air
volume units
365-Day real time clock with automatic Daylight Savings
time adjustment
Occupancy Schedule allowing two schedules per day
20 Holiday schedules with programmable schedules that
can start at any time, day or night
Patented Comfort Ventilation operation for economical
and comfortable economizer operation
Demand Ventilation option to assure proper IAQ condi-
tions based on available space or return air CO
2
levels
Temperature/Humidity programming algorithm allows
programmable limits to help control humidity in the space
Smoke Purge automatically ventilates the space when
smoke is detected
Monitors dirty filters and proves airflow before starting
heating or cooling
Intelligent recovery to bring the space temperature up to
occupied setting quicker and more economically