Omega CN1166 Video Game Controller User Manual


 
APPENDIX A PRODUCT
SPECIFICATION
UNIVERSAL INPUT
General
Maximum per Controller: One
Input Sample Rate: Four samples/second
Digital Input Filter: Time constant selectable from front panel -
0.0 (i.e. OFF), 0.5 to 100.0 seconds in
0.5-second increments.
Input Resolution: 14 bits approximately; always four times
better than display resolution.
Input Impedance: Greater than 100M
W resistive (except for
DC mA and V inputs).
Isolation: Universal input isolated from all outputs
except SSR at 240V AC.
Process Variable Offset:
Adjustable ±input span.
A-1 Volume II S077-A
Type Input Range Displayed Code Type Input Range Displayed Code
R
0 - 1650°C
1127 J
32 - 1401°F
1420
R
32 - 3002°F
1128 T
-200 - 262°C
1525
S
0 - 1649°C
1227 T
-328 - 503°F
1526
S
32 - 3000°F
1228 T
0.0 - 260.6°C
1541
J
0.0 - 205.4°C
1415 T
32.0 - 501.0°F
1542
J
32.0 - 401.7°F
1416 K
-200 - 760°C
6726
J
0 - 450°C
1417 K
-328 - 1399°F
6727
J
32 - 842°F
1418 K
-200 - 1373°C
6709 *
J
0 - 761°C
1419 * K
-328 - 2503°F
6710
* Default Continued overleaf....................