- INSTRUCTIONS -
10 Camera Adaptor for LEF/LDF System
WIRING DIAGRAM:
Pg. 1
The MYW-P10L adaptor allows up to 10 2-wire video door stations to be used with the LEF series Master
Sentry System. MY or MK PanTilt series video door stations may be used with the MYW-P10L. CCTV
cameras may be connected through the MYW-P10L using the MYW-MD/B adaptor. Door release is
available through the intercom system (LEF or LDF only).
NOTES:
1. The MONITOR button, Auto-Scan
Duration, and Monitor Receive
Volume switches on the front of the
unit are non-functional.
2. Diodes shown must be used
when using RY-PA door release
relays. They are 1N4007, and are
included in the box with the unit.
3. When initializing the MYW-P10L
with CCTV cameras,a constant call
tone will be heard on the LEF
master for approx. 1 minute
during this process. To avoid this,
unplug the PS-1225UL for the LEF
system before turning on the MYW-
P10L, then plug back in when the
initialization is complete. The
constant tone will also be heard if
the MYW-P10L loses power, or if
it is turned off.
4. Only wiring concerning the MYW-
P10L is shown here. For complete
installation and wiring information,
please see the standard LEF
instructions.
1205
MK-DAC
RY-PA
RY-PA
RY-PA
RY-PA
Yellow
Yellow
Yellow
Yellow Black
Black
Black
Black
To Strike
& Power
#1
To Strike
& Power
#2
To Strike
& Power
#3
To Strike
& Power
#4
Yellow Black
To Strike
& Power
#5
RY-PA
MK-DAC
MK-DBC
MK-DBC
MK-DGC
Any MK-series
video door station
is compatible with
this system.
B1 1A1
B2 1A2
2A1
U1 2A2
U2
3A1
3A2
+18V
-18V 4A1
4A2
5A1
5A2
~
10A1
10A2
1
2
3
4
5
6
7
8
9
10
E
+12V
-12V
K1
K2
K3
K4
K5
~
K10
MYW-P10L
A1
A2
A1
A2
A1
A2
A1
A2
A1
A2
1
2
3
4
5
6
7
8
9
10
C
E
R
Y
+
-
L
K1
K2
K3
K4
K5
~
K10
1
2
3
4
5
6
7
8
9
10
C
E
R
Y
+
-
L
K1
K2
K3
K4
K5
~
K10
LEF-10
LEF-10
+
-
PS-1225UL
A1
A2
B1
B2
U1
U2
+
-
B1
B2
A1
A2
U1
U2
+
-
MYH-CU
MYH-CU
+
-
PS-1820UL
INSIDE MYW-P10L CHASSIS
EXTERNAL TERMINAL BLOCK
MYW-P10L TERMINAL DEFINITIONS:
Found inside MYW-P10L
nA1 Input from MY/MK Series
nA2 video door station
B1 Video signal output
B2 to monitors
U1 Video activation
U2 to monitors
18V+ Positive 18V DC
18V- Negative
N1,N2 Unused
Found in external terminal box
1 ~ 10 Audio communication
E Common communication
12V+ Positive 12V DC
12V- Negative
K1 ~ K10 Video control terminals
To: Monitor TV
and/or Time-Lapse
VCR, ect.
(525) line only
CN-9
*When using door release relays: Install cathode side of
supplied 1N4007 diodes directly to K terminals of MYW-P10L,
and connect black wire of RY-PA to anode side of diode.
Do not install diodes on K terminals at the LEF master station.
*